ATD Tools ATD5289 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro ne ATD Tools ATD5289. ATD Tools ATD5289 User's Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 12
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
ATD5289 MADE IN MEXICO FOR 25-50 LB. BUCKETS
RETAIN THIS MANUAL FOR FUTURE REFERENCE TO IMPORTANT WARNINGS AND
OPERATING AND MAINTENANCE INSTRUCTIONS.
PROPER USE AND MAINTENANCE OF THIS EQUIPMENT IS THE RESPONSIBILITY OF THE
OWNER AND/OR OPERATOR.
DO NOT USE THIS EQUIPMENT UNLESS YOU HAVE CAREFULLY READ AND
UNDERSTAND THE INSTRUCTIONS AND WARNINGS IN THIS MANUAL.
! WARNING !
NEVER exceed the stated maximum working pressure of the pump or of the lowest rated component in your
system.
NEVER modify any part of this equipment.
NEVER use combustible gas with this equipment.
NEVER attempt repairs while the system is under pressure.
NEVER attempt to disassemble the equipment while the system is under pressure.
ALWAYS tighten fluid connections before using this equipment
ALWAYS read/follow the fluid manufacturer’s recommendations regarding fluid compatibility.
ALWAYS read/follow the fluid manufacturer’s recommendations regarding the use of protective clothing
and equipment.
ALWAYS use an air line filter/moisture eliminator at the air inlet for the pump.
ALWAYS use air line lubrication.
REGULARLY check all equipment and repair/replace worn or damaged parts immediately.
FAILURE TO HEED THESE WARNINGS INCLUDING OVERPRESSURIZING,
ALTERING PARTS, USE OF INCOMPATIBLE FLUIDS, MISUSE, OR USE OF
DAMAGED/WORN PARTS MAY RESULT IN EQUIPMENT DAMAGE,
PROPERTY DAMAGE, FIRE, EXPLOSION AND/OR SERIOUS PERSONAL
INJURY.
SAFETY INSTRUCTIONS
Extreme caution should be used when operating this equipment as it generates very high fluid pressure.
Leaks from loose or ruptured components or material from dispensing valve can inject fluid through the skin
causing serious bodily injury and possible need for amputation. Always wear protection to prevent material
splashing onto skin or into eyes.
IMPORTANT:
GET EMERGENCY MEDICAL CARE IMMEDIATELY IF ANY FLUID APPEARS TO
PENETRATE THE SKIN! INFORM PHYSICIAN OF EXACTLY WHAT WAS INJECTED. PLEASE
DO NOT TREAT THIS INJURY AS A SIMPLE CUT.
AIR OPERATED CHASSIS PUMP
50:1 RATIO, OUTPUT
– 80 CU. IN./MIN.
MIN. AIR PRESSURE – 30 PSI
MAX. AIR PRESSURE – 120 PSI
MAX. OUTPUT PRESSURE – 7500 PSI
RECOMMENDED OPERATING PRESSURE 80-100 PSI
GREASE TYPE: NLGI #2
(maximum for effective
p
erformance)
OWNERS MANUAL
Zobrazit stránku 0
1 2 3 4 5 6 ... 11 12

Shrnutí obsahu

Strany 1 - ! WARNING !

ATD5289 MADE IN MEXICO FOR 25-50 LB. BUCKETS RETAIN THIS MANUAL FOR FUTURE REFERENCE TO IMPORTANT WARNINGS AND OPERATING AND MAIN

Strany 4

84191ME BAND DOLLY PARTS BREAKDOWN

Strany 5

! WARNING ! – RELIEF PROCEDURE DO NOT EVER point the dispensing valve at another person. DO NOT EVER attempt to stop material from the dispensing

Strany 6 - Warning:

Instruction for Assembly of ATD5289 Lubrigun Unpack ATD5289 Assembly from Carton This should include the following pieces: Pump, Drum Cover (Red)

Strany 7

Instruction for Assembly of ATD5289 Lubrigun Additional Instruction Notes… Ensure that the Muffler ATD5317 is inserted in the correct orifice. T

Strany 8

Trouble Shooting Guide for Pumps ATD5217 – ATD5219 –ATD5289 PROBLEM: SOLUTION: Warning: If the Air is connected to the pump, consider the pump t

Strany 9

QUESTION YES NO Does the pump Air Motor operate when it is removed from the Grease? Yes? Then put the pump back in the grease. Remove the hose f